Summary for Test 2025-10-30-50-6
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 1000760 DEA: 101L2804 EFIS: 1020000103 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-4-20.5/20.8 |
| Award Date | 01/28/2025 |
| Closeout Date | Not set |
| Work Description | INSTALL LEFT-TURN CHANNELIZATION. |
| Location Description | SAN JOAQUIN COUNTY NEAR STOCKTON FROM 0.2 MILE WEST OF WALKER LANE TO 0.1 MILE EAST OF WALKER LANE |
| QA Service Level | 1 (Verified on 11/12/2024) |
Sample Information
| Sample Taken Date | 10/30/2025 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 WMA-SP 25%Rap |
| The quantity of what the sample constitutes | 2 Cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | Trevor | Last name of sampler or witnessed by | Fulkerson |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Vernalis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 0300001 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | 1 | |
| Sublot number | 1 | Tank number | |
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-10-30-50
DIME Test ID: 2025-10-30-50-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-12-02
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 11/25/2025
Any material loss from containers during heating process/testing?: no data
Mass of container #1 before test (m1i): 210.029 grams
Mass of container #2 before test (m2i): 209.137 grams
Mass of container #1 after test (m1f): 209.972 grams
Mass of container #2 after test (m2f): 209.074 grams
Mass of empty container #1: 175.257 grams
Mass of empty container #2: 174.042 grams
Mass correction factor: 0.030
Average mass change: -0.142 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 12/2/2025 ✔