Summary for Test 2025-10-30-50-4
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 1000760 DEA: 101L2804 EFIS: 1020000103 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-4-20.5/20.8 |
| Award Date | 01/28/2025 |
| Closeout Date | Not set |
| Work Description | INSTALL LEFT-TURN CHANNELIZATION. |
| Location Description | SAN JOAQUIN COUNTY NEAR STOCKTON FROM 0.2 MILE WEST OF WALKER LANE TO 0.1 MILE EAST OF WALKER LANE |
| QA Service Level | 1 (Verified on 11/12/2024) |
Sample Information
| Sample Taken Date | 10/30/2025 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 WMA-SP 25%Rap |
| The quantity of what the sample constitutes | 2 Cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | Trevor | Last name of sampler or witnessed by | Fulkerson |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Vernalis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 0300001 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | 1 | |
| Sublot number | 1 | Tank number | |
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-10-30-50
DIME Test ID: 2025-10-30-50-4
Testing Lab: Atlas - Denver
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2025-12-02
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 11/25/2025
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of test #3 (D3): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Ductility
Test was verified on 12/2/2025 ✔