Summary for Test 2025-11-17-3-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1000402
DEA: 11430384
EFIS: 1118000114
DIST-CO-RTE-PM11-SD-805-23.7/28.5
Award Date10/09/2024
Closeout DateNot set
Work DescriptionREPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
QA Service Level1 (Verified on 11/18/2024)

Sample Information

Sample Taken Date11/17/2025 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/20/2025
Sample typeQuality Assurance A brief description of the sample3/4" x 2" A325 HDG
The quantity of what the sample constitutes4 Bolts From where was the sample collectedDistributor
First name of sampler or witnessed byJacob Garcia Last name of sampler or witnessed byGarcia
Title of samplerQA Inspector Telephone number of sampler7606866753
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAbaba Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL169-074-25 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)MT217 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM A325
Bolt Length(s)2" Nut SpecificationN/A
Washer SpecificationN/A FinishASTM A153/F2329
Diameter/Size3/4" Bolt Mfg. Lot Number1333825-001-002, B2341961G1
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2025-11-17-3
DIME Test ID: 2025-11-17-3-3
Testing Lab: Kleinfelder - Rancho Cordova
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2025-12-09

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 12/01/2025
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AB2341961G10.754619000NAAtlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/9/2025