Summary for Test 2025-10-17-52-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000365
DEA: 033H9014
EFIS: 0323000075
DIST-CO-RTE-PM03-SOL,YOL-50,80,113-Var
Award Date09/27/2024
Closeout DateNot set
Work DescriptionHMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location DescriptionSOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/17/2024)

Sample Information

Sample Taken Date10/17/2025 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/06/2025
Sample typeQuality Assurance A brief description of the sample3/4" RHMA-G
The quantity of what the sample constitutes2 Boxes From where was the sample collectedSource
First name of sampler or witnessed bySergio Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 25-261 Linked DIME Sample ID2025-10-17-41
The fabricator/manufacturer/facility nameDeSilva Gates Marysville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number3 HMA Mix NumberMD 6617
Binder content (%)7.5 Virgin binder PG
Design binder PG PG 64-16 Binder SupplierValero
RAP content (%)0 WMA AdditivesYes
Antistrip typeEvotherm M1

Test Details

DIME Sample ID: 2025-10-17-52
DIME Test ID: 2025-10-17-52-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-26

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 11/25/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2148.1 g
Mass Loss: 178.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.92 %
General comments (publicly viewable) (Max 1000 characters): R1 OBC 7.5%

Test was verified on 11/26/2025