Summary for Test 2025-10-17-52-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 |
|---|---|
| DIST-CO-RTE-PM | 03-SOL,YOL-50,80,113-Var |
| Award Date | 09/27/2024 |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS. |
| Location Description | SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/17/2024) |
Sample Information
| Sample Taken Date | 10/17/2025 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/06/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" RHMA-G |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Sergio | Last name of sampler or witnessed by | Tostado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Daily 25-261 | Linked DIME Sample ID | 2025-10-17-41 |
| The fabricator/manufacturer/facility name | DeSilva Gates Marysville | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 3 | HMA Mix Number | MD 6617 |
| Binder content (%) | 7.5 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 0 | WMA Additives | Yes |
| Antistrip type | Evotherm M1 |
Test Details
DIME Sample ID: 2025-10-17-52
DIME Test ID: 2025-10-17-52-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-26
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 11/25/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2148.1 g
Mass Loss: 178.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.92 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 7.5%
Test was verified on 11/26/2025 ✔