Summary for Test 2025-06-17-169-3
Test performed: CTM 504-June 2010Project Information
| Project Identifiers | Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 |
|---|---|
| DIST-CO-RTE-PM | 03-SOL,YOL-50,80,113-Var |
| Award Date | 09/27/2024 |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS. |
| Location Description | SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/17/2024) |
Sample Information
| Sample Taken Date | 06/17/2025 | Sample Unique Key | 169 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/18/2025 | Sample type | Quality Control |
| A brief description of the sample | 4x8 Cylinders | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Osvaldo |
| Last name of sampler or witnessed by | Ruiz | Title of sampler | QC Field Technician |
| Telephone number of sampler | Laboratory sample identification | 1626827 Set 1 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Cemex Fairfield | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | Sign A4, STA 240+50 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 16286827 |
|---|---|---|---|
| The truck number from where the sample was collected | Load 2 | The batch plant ticket number from where the sample was collected | 31643756 |
| Concrete batch plant | Cemex | The fabricator/manufacturer designation for the sample | Set 1 |
| A detailed description of where the material sample was collected | Sign A4, STA 240+50 | Where the material sample would have been placed if not sampled | Sign A4 |
| From Lot No. | 1 | Bag Lot No. | 1 |
Test Details
DIME Sample ID: 2025-06-17-169
DIME Test ID: 2025-06-17-169-3
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2025-11-21
Test Results
Input Type: Calculated
Tester's full name: Osvaldo Ruiz
Date of test: 06/17/2025
Air Content: 2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/21/2025 ✔