Summary for Test 2025-11-03-55-8
Test performed: AASHTO T269-24E25Project Information
| Project Identifiers | Project ID: 1001127 DEA: 112N2064 EFIS: 1123000285 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-94-1.6/R13.3 |
| Award Date | 06/03/2025 |
| Closeout Date | Not set |
| Work Description | POLYESTER CONCRETE, METHACRYLATE, JOINT SEALS AND APPROACH SLABS. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM 22ND STREET OVERCROSSING TO AVOCADO BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 06/02/2025) |
Sample Information
| Sample Taken Date | 11/03/2025 | Sample Unique Key | 55 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/04/2025 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | Telephone number of sampler | 6199366795 | |
| Laboratory sample identification | 25-11-03-55 | Linked DIME Sample ID | 2025-11-03-54 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 21217105 MM | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-11-03-55
DIME Test ID: 2025-11-03-55-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2025-11-20
Test Results
Is the sample lab compacted or field compacted?: Lab compacted
Number of tests: 3
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 11/18/2025
Bulk Specific Gravity: 2.317
Bulk Specific Gravity 2: 2.303
Bulk Specific Gravity 3: 2.318
Theoretical Maximum Specific Gravity: 2.532
Percent Air Voids: 8.5 %
Percent Air Voids 2: 9.0 %
Percent Air Voids 3: 8.5 %
Average Percent Air Voids: 8.7 %
General comments (publicly viewable) (Max 1000 characters): Does not comply
Test was verified on 11/20/2025 ✔