Summary for Test 2025-11-04-48-5
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1000510 DEA: 060W79U4 EFIS: 0622000189 |
|---|---|
| DIST-CO-RTE-PM | 06-KER,TUL-99-56.4/57.6,0.0/13.5 |
| Award Date | 04/10/2025 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC. |
| Location Description | KERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING |
| QA Service Level | 1 (Verified on 08/26/2024) |
Sample Information
| Sample Taken Date | 11/04/2025 | Sample Unique Key | 48 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2025 |
| Sample type | Quality Control | A brief description of the sample | 1", WCS |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Brenda | Last name of sampler or witnessed by | Amaya |
| Title of sampler | QC Field Technician | Telephone number of sampler | |
| Laboratory sample identification | Set 1 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CalPortland Tulare | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Sound Wall 3 | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | SMARA 91-54-0038 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Set 1 | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | Batch Plant Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 163457 | Lot number | 1 |
| Sublot number | 1 | Aggregate Mix Number | 163457 |
Test Details
DIME Sample ID: 2025-11-04-48
DIME Test ID: 2025-11-04-48-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-11-20
Test Results
Number of tests: 1
Input Type: Calculated
Tester's full name: David Silva
Date of test: 11/05/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 0
Sand reading (test 1): 0
Sand equivalent (test 1): 88
Sand equivalent before temperature correction: 0
Sand equivalent after temperature correction: 88
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2025 ✔