Summary for Test 2025-11-04-6-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 11/04/2025 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/13/2025 | Sample type | Quality Assurance |
| A brief description of the sample | Zaploock #5 Rebar Coupler | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jose Fabian |
| Last name of sampler or witnessed by | Velasco Diaz | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nucor BarSplice | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A615 |
| Material Grade | 60 | Rebar Manufacturer | Cascade |
| Coupler Manufacturer | Barsplice and Nucor | Intermediate Assembler or Fabricator | |
| Rebar Size | #5 | Coupler Model | Zap Screwlok Type 2 |
| Coating Standards | ASTM A934 epoxy | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 74134732 | Rebar Heat Number(s) | 1201060250 |
| Rebar Size 2 | Coupler Unique ID | SL-17-03 |
Test Details
DIME Sample ID: 2025-11-04-6
DIME Test ID: 2025-11-04-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-11-20
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 11/20/2025
UTM: NA
Halo ID: na
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 5 | 0.31 | 0.006 | 25300 | 81500 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 5 | 0.31 | 0000 | 25490 | 82000 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 5 | 0.31 | 0000 | 26770 | 86500 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 5 | 0.31 | 0000 | 25880 | 83500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2025 ✔