Summary for Test 2025-11-05-77-3

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1001169
DEA: 07314524
EFIS: 0722000300
COOP: 075283
DIST-CO-RTE-PM07---
Award Date07/03/2023
Closeout DateNot set
Work DescriptionI-105 METRO Express Lanes Project
Location DescriptionLA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6
QA Service Level2 (Verified on 04/11/2025)

Sample Information

Sample Taken Date11/05/2025 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/05/2025
Sample typeQuality Assurance A brief description of the sampleISR Beams
The quantity of what the sample constitutes10 CY From where was the sample collectedJob Site
First name of sampler or witnessed byAleksey Last name of sampler or witnessed bySouglobov
Title of samplermaterials Tester Telephone number of sampler7075835090
Laboratory sample identification110425-ISR-001 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberFID-0605-1
The truck number from where the sample was collectedTruck or Ticket 21 The batch plant ticket number from where the sample was collectedLoad 3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampledJobsite
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-11-05-77
DIME Test ID: 2025-11-05-77-3
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-11-19

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 11/08/2025
Identification number: 110425-ISR-001
Width of specimen: 6.0625 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 5.9375 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 5.9375 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9642 lb
Maximum load applied 2: 9325 lb
Maximum load applied 3: 9276 lb
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 820 psi
Modulus of rupture 2: 790 psi
Modulus of rupture 3: 840 psi
Modulus of rupture average: 820 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2025