Summary for Test 2025-11-19-6-1
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 995242 DEA: 060Y1304 EFIS: 0619000010 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-33-40.4/59.3 |
| Award Date | 06/20/2024 |
| Closeout Date | 09/10/2026 |
| Work Description | COLD PLANE, PLACE HMA AND RHMA-G, AND REPLACE CULVERTS. |
| Location Description | KERN COUNTY ABOUT 8 MILES NORTH OF MCKITTRICK FROM CYMRIC WASH BRIDGE TO 0.8 MILE SOUTH OF ROUTE 46 |
| QA Service Level | 1 (Verified on 09/03/2024) |
Sample Information
| Sample Taken Date | 11/19/2025 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/19/2025 | Sample type | Acceptance |
| A brief description of the sample | 1/2" RHMA- G | The quantity of what the sample constitutes | L2SL53 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Matt |
| Last name of sampler or witnessed by | Decker | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Solari | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | 3905097 |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 2 |
| Sublot number | 53 | HMA Mix Number | |
| Binder content (%) | 0.0 | Virgin binder PG | PG 64-16 |
| Design binder PG | PG 64-16 | Binder Supplier | San Juaquin Refinery |
| RAP content (%) | 0 | WMA Additives | Yes |
| Antistrip type | Hydrated Lime |
Test Details
DIME Sample ID: 2025-11-19-6
DIME Test ID: 2025-11-19-6-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-11-21
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 11/19/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7328.1 grams
Mass of oven-dry sample in air for Sample 1: 1662.1 grams
Mass of container filled with the sample and water for Sample 1: 8311.2 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.448
Theoretical maximum density at 25°C (77°F): 2441 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-0Y1304_37045_251119_L2SL53_T209 | 113.17 KB | 11/19/2025 | 2025-11-19-6-1 | Info |
Test was verified on 11/21/2025 ✔