Summary for Test 2025-09-25-95-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1001605 DEA: 114B0044 EFIS: 1122000173 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-54-9.5,0.0/6.4 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Construct Middle Mile Broadband Network. |
| Location Description | IN SAN DIEGO COUNTY IN AND NEAR SAN DIEGO, NATIONAL CITY, AND CHULA VISTA ON ROUTE 5 AT 0.1 MILE NORTH OF SWEETWATER RIVER BRIDGE AND ON ROUTE 54 FROM ROUTE 5/54 SEPARATION TO 0.4 MILE EAST OF SWEETWATER ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/18/2025) |
Sample Information
| Sample Taken Date | 09/25/2025 | Sample Unique Key | 95 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/26/2025 | Sample type | Quality Assurance |
| A brief description of the sample | Normal Production | The quantity of what the sample constitutes | 2 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Mohammed |
| Last name of sampler or witnessed by | Masud | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Otay | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 320200 Otay Val | |
| Binder content (%) | 4.9 | Virgin binder PG | PG58-16 |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 22 | WMA Additives | No |
| Antistrip type | No |
Test Details
DIME Sample ID: 2025-09-25-95
DIME Test ID: 2025-09-25-95-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-12-02
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 11/18/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4026.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 5551.6 g
Mass of HMA Sample prior to ignition: 1525.6 g
Mass Loss: 89.9 g
Mass of aggregate remaining after ignition: 1435.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.59 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.30 %
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 12/2/2025 ✔