Summary for Test 2025-06-26-123-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date06/26/2025 Sample Unique Key123
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2025
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 3/4-inch Type A HMA (PG 70-10)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of sampler Telephone number of sampler
Laboratory sample identificationD79924 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River — Orland Plant (Orland, CA) Transportation Laboratory (TL) Number858138
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3907716

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberJMF3513202517
Binder content (%)4.5 Virgin binder PG PG 70-10
Design binder PG PG 70-10 Binder SupplierPacific Northwest (Stockton, CA)
RAP content (%)15 WMA AdditivesNo
Antistrip typeLime

Test Details

DIME Sample ID: 2025-06-26-123
DIME Test ID: 2025-06-26-123-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2025-11-20

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?: Lab compacted
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/01/2025
123
2.455 2.450 2.446
2.556

4.0 %

4.1 %

4.3 %

4.1 %
General comments (publicly viewable) (Max 1000 characters): AASHTO T 269: Pa=4.1%; MS-2: VMA=13.8%, VFA=70.1%, DP=0.9

Test was verified on 11/20/2025