Summary for Test 2025-10-03-64-3

Test performed: ASTM D5329-20

Project Information

Project IdentifiersProject ID: 1000176
DEA: 034H76U4
EFIS: 0323000040
DIST-CO-RTE-PM03-BUT-32-5.0/10.2
Award Date06/17/2024
Closeout DateNot set
Work DescriptionREHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS
Location DescriptionBUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32
QA Service Level1 (Verified on 04/18/2024)

Sample Information

Sample Taken Date10/03/2025 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/04/2025
Sample typeQuality Assurance A brief description of the sample64-16
The quantity of what the sample constitutes1 CAN OF RUBBER From where was the sample collectedSource
First name of sampler or witnessed byMARK Last name of sampler or witnessed byatteberry
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKNIFE RIVER Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form955752 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-10-03-64
DIME Test ID: 2025-10-03-64-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2025-11-18

Test Results


Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 11/18/2025
Temperature: 25 C
Ball Penetration (P1): 5 mm
Final Dial reading (F1): 80 mm
Ball Penetration (P2): 4 mm
Final Dial reading (F2): 79 mm
Ball Penetration (P3): 6 mm
Final Dial reading (F3): 84 mm
Resilience 1: 25 %
Resilience 2: 25 %
Resilience 3: 22 %
Average Resilience: 24 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): RESILIENCE

Test was verified on 11/18/2025