Summary for Test 2025-11-05-37-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date11/05/2025 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/06/2025
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byBONNIE Last name of sampler or witnessed byB
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVANGUARD Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected7025
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collected215 SB STA: 611+00 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-11-05-37
DIME Test ID: 2025-11-05-37-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-11-18

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/12/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Average diameter of cylinder 3: 6.02 in
Maximum load on cylinder 1: 147150 lb
Maximum load on cylinder 2: 150020 lb
Maximum load on cylinder 3: 149455 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Cross sectional area of cylinder 3: 28.46 in^2
Compressive strength of cylinder 1: 5190.0 psi
Compressive strength of cylinder 2: 5270.0 psi
Compressive strength of cylinder 3: 5250 psi
Compressive strength (to nearest 10 psi): 5240 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2025