Summary for Test 2025-10-21-35-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date10/21/2025 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/27/2025
Sample typeAcceptance A brief description of the sample3/4" HMA ASP R25% EVO .25%
The quantity of what the sample constitutes2 BOXES HMA, 1 QT PG64-16 From where was the sample collectedManufacturer
First name of sampler or witnessed byJACOB Last name of sampler or witnessed byRJ NOBLE - QC
Title of sampler Telephone number of sampler
Laboratory sample identification0665A-25 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number36R2503SPWEC
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-10-21-35
DIME Test ID: 2025-10-21-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-18

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Vince Onoh
Date of test: 10/28/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2176.1 g
Mass Loss: 118.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.65 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.65 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2025