Summary for Test 2017-12-15-3-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212205
DEA: 044K7104
EFIS: 0417000340
DIST-CO-RTE-PM04-SCL-35-9.5, 9.50
Award Date03/28/2017
Closeout Date02/22/2019
Work Descriptionconstruct tie-back wall
Location DescriptionNot set
QA Service Level1 (Verified on 06/22/2017)

Sample Information

Sample Taken Date12/15/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing12/15/2017 Sample typeQuality Assurance
A brief description of the sample1/2 A325 HDG The quantity of what the sample constitutes3 of 7
From where was the sample collectedFabricator First name of sampler or witnessed byScott
Last name of sampler or witnessed byLeavitt Title of samplerQA Inspector
Telephone number of sampler510 590-0116 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUIS
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormS28-383-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)DL16101278 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationA325
Bolt Length(s)4 Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size1/2 Bolt Mfg. Lot NumberG9122
Rocap Test Requirement(s)No Lubricant Requirements(s)No
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-12-15-3
DIME Test ID: 2017-12-15-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-12-26

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 12/19/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AS28383171/2\"200098910A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 12/19/2017 ✔