Summary for Test 2025-11-10-9-3

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1000682
DEA: 09379104
EFIS: 0919000005
DIST-CO-RTE-PM09-INY-395-91.6/100.8
Award Date02/20/2025
Closeout DateNot set
Work DescriptionCONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS.
Location DescriptionINYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date11/10/2025 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/10/2025
Sample typeQuality Assurance A brief description of the sampleHMA181
The quantity of what the sample constitutes118-122K Air Void Milestone From where was the sample collectedJob Site
First name of sampler or witnessed byJerid Last name of sampler or witnessed byKupelian
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRHB Plant Independence Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-11-10-9
DIME Test ID: 2025-11-10-9-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-14

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 11/14/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4255.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 6433.6 g
Mass of HMA Sample prior to ignition: 2178.0 g
Mass Loss: 115.6 g
Mass of aggregate remaining after ignition: 2062.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.38 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.93 %
General comments (publicly viewable) (Max 1000 characters): HMA-181

Test was verified on 11/14/2025