Summary for Test 2025-10-30-47-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001120 DEA: 033G6204 EFIS: 0325000037 |
|---|---|
| DIST-CO-RTE-PM | 03-YOL-5-R22.8/R28.9 |
| Award Date | 06/03/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT AND HMA (TYPE A). |
| Location Description | YOLO COUNTY NEAR DUNNIGAN FROM 0.2 MILE NORTH OF ROUTE 505/5 SEPARATION TO THE COLUSA COUNTY LINE |
| QA Service Level | 1 (Verified on 04/02/2025) |
Sample Information
| Sample Taken Date | 10/30/2025 | Sample Unique Key | 47 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/06/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA w/ 15% RAP |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Sergio | Last name of sampler or witnessed by | Tostado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Daily 25-248 | Linked DIME Sample ID | 2025-10-30-40 |
| The fabricator/manufacturer/facility name | Teichert Woodland | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 5 | HMA Mix Number | 30640432407V |
| Binder content (%) | 4.7 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 15 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-10-30-47
DIME Test ID: 2025-10-30-47-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-13
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 11/13/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2158.1 g
Mass Loss: 132.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.90 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.23 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 4.7%
Test was verified on 11/13/2025 ✔