Summary for Test 2017-12-18-11-1

Test performed: CTM 385-November 2016

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date12/18/2017 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing12/18/2017 Sample typeQuality Control
A brief description of the sampleTEST The quantity of what the sample constitutesTEST
From where was the sample collectedOther First name of sampler or witnessed byTEST
Last name of sampler or witnessed byTEST Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTEST
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCrumb Rubber Modifier CRM TypeHigh Natural
Crumb Rubber Modifier Mix NumberNot set

Test Details

DIME Sample ID: 2017-12-18-11
DIME Test ID: 2017-12-18-11-1
Testing Lab: CT HQ - QAM Sacramento Field Laboratory
Test Method: CTM 385-November 2016: Method of Test for Sampling and Testing Crumb Rubber Modifier (CRM)
Test Release Date: 2017-12-25

Test Results


CRM Gradation Type: High Natural
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 12/18/2017
High Natural CRM gradation (% passing No. 10 sieve): 100 %
Wire in CRM: no data
Fabric in CRM: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/18/2017 ✔