Summary for Test 2025-10-27-33-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995031 DEA: 023H82U4 EFIS: 0223000011 |
|---|---|
| DIST-CO-RTE-PM | 02-LAS-44-0.0/37.2 |
| Award Date | 10/24/2023 |
| Closeout Date | 07/03/2025 |
| Work Description | REPLACE AC SURFACING, PLACE RHMA, HMA, THERMOPLASTIC TRAFFIC STRIPE. |
| Location Description | LASSEN COUNTY ABOUT 9 MILES EAST OF OLD STATION FROM SHASTA COUNTY LINE TO ROUTE 36 |
| QA Service Level | 1 (Verified on 08/10/2023) |
Sample Information
| Sample Taken Date | 10/27/2025 | Sample Unique Key | 33 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/03/2025 | Sample type | Verification |
| A brief description of the sample | 1 box of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28) with 22.0% RAP and virgin PG 58-34 from Albina (K-Falls) | The quantity of what the sample constitutes | 80 tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brandon |
| Last name of sampler or witnessed by | White | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D80113 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Hat Creek Construction and Materials - Ward Lake Plant (Litchfield, CA) | |
| Transportation Laboratory (TL) Number | 848640 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 5.7 | Virgin binder PG | |
| Design binder PG | PG 64-28 | Binder Supplier | Albina (Klamath Falls, OR) |
| RAP content (%) | 22 | WMA Additives | No |
| Antistrip type | 1% Lime |
Test Details
DIME Sample ID: 2025-10-27-33
DIME Test ID: 2025-10-27-33-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-10
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 11/05/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3157.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 5244.0 g
Mass of HMA Sample prior to ignition: 2087.0 g
Mass Loss: 141.6 g
Mass of aggregate remaining after ignition: 1945.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.87 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.77 %
General comments (publicly viewable) (Max 1000 characters): Pb=5.77%, TV=5.67
Test was verified on 11/10/2025 ✔