Summary for Test 2025-08-01-92-3
Test performed: ASTM D5329-20Project Information
| Project Identifiers | Project ID: 1000891 DEA: 120U8104 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-11.0/22.5 |
| Award Date | 04/17/2025 |
| Closeout Date | Not set |
| Work Description | REMOVE AND REPLACE RHMA, PAVEMENT MARKING AND ROADSIDE SIGN. |
| Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS FROM ROUTE 5/22/57 SEPARATION TO 0.3 MILE SOUTH OF LOS ANGELES COUNTY LINE |
| QA Service Level | 1 (Verified on 01/23/2025) |
Sample Information
| Sample Taken Date | 08/01/2025 | Sample Unique Key | 92 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2025 |
| Sample type | Verification | A brief description of the sample | JMF Verification |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | Capacete QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | All American Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2025-08-01-92
DIME Test ID: 2025-08-01-92-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2025-11-13
Test Results
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 11/07/2025
Temperature: 25 C
Ball Penetration (P1): 5 mm
Final Dial reading (F1): 75 mm
Ball Penetration (P2): 3 mm
Final Dial reading (F2): 72 mm
Ball Penetration (P3): 4 mm
Final Dial reading (F3): 74 mm
Resilience 1: 30 %
Resilience 2: 31 %
Resilience 3: 30 %
Average Resilience: 30 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/13/2025 ✔