Summary for Test 2017-11-28-4-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 212962 DEA: 100W6204 EFIS: 1012000020 |
|---|---|
| DIST-CO-RTE-PM | 10-MER-5-0.4/0.9 |
| Award Date | 01/23/2020 |
| Closeout Date | 10/21/2022 |
| Work Description | Erreca Rest Area Wastewater System |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 03/13/2020) |
Sample Information
| Sample Taken Date | 11/28/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2017 |
| Sample type | Preliminary | A brief description of the sample | Soil |
| The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Hagy |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | 17SOIL-0371 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C835558 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Borings A-17-001, -002, -003 |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2017-11-28-4
DIME Test ID: 2017-11-28-4-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2017-12-18
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 12/18/2017
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 12733 grams | ||||||
| 0.0 grams | 100 % | |||||
| 31.0 grams | 100 % | |||||
| 84.0 grams | 99 % | |||||
| 137.0 grams | 99 % | |||||
| 208.0 grams | 98 % | |||||
| 847.0 grams | 93 % | |||||
| 847.0 grams | 93 % | |||||
| 12733.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/18/2017 ✔