Summary for Test 2025-11-05-22-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993798
DEA: 09366804
EFIS: 0916000021
DIST-CO-RTE-PM09-INY-395-117.3/117.9
Award Date04/03/2025
Closeout DateNot set
Work DescriptionMEADOW FARMS ADA
Location DescriptionINYO COUNTY NEAR BISHOP FROM 0.1 MILE EAST OF SEE VEE LANE TO BARLOW LANE
QA Service Level1 (Verified on 08/14/2023)

Sample Information

Sample Taken Date11/05/2025 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/05/2025
Sample typeAcceptance A brief description of the sample3/4" Coldfeed Aggs
The quantity of what the sample constitutes1 Bag of Coldfeed Aggregate From where was the sample collectedSupplier
First name of sampler or witnessed byDylan Last name of sampler or witnessed byCarapazza
Title of sampler Telephone number of sampler
Laboratory sample identificationCF-04 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite 5 Bridges Plant Bishop Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Granite 5 Bridges
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedColdfeed Chute
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-11-05-22
DIME Test ID: 2025-11-05-22-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-11-07

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 11/07/2025
Cumulative Mass RetainedCumulative Percent Passing
5072.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
411.6 grams92 %
1122.4 grams78 %
1589.7 grams69 %
2528.3 grams50 %
482.4 grams
151.4 grams34 %
241.6 grams25 %
311.3 grams18 %
369.8 grams12 %
422.2 grams6 %
452.5 grams3.1 %
456.5 grams
General comments (publicly viewable) (Max 1000 characters): CF-04

Test was verified on 11/7/2025