Summary for Test 2025-10-13-20-7
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 212779 DEA: 021H5804 EFIS: 0216000024 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-58.4/R78.4 |
| Award Date | Not set |
| Closeout Date | 10/03/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 10/13/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 64-28m |
| The quantity of what the sample constitutes | 2 cans. split sample | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Riley | Last name of sampler or witnessed by | M |
| Title of sampler | consultant | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Western NV Materials, Spanish Springs | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 972020 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-10-13-20
DIME Test ID: 2025-10-13-20-7
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-11-06
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 10/29/2025
Any material loss from containers during heating process/testing?: no data
Mass of container #1 before test (m1i): 204.114 grams
Mass of container #2 before test (m2i): 205.106 grams
Mass of container #1 after test (m1f): 203.937 grams
Mass of container #2 after test (m2f): 204.982 grams
Mass of empty container #1: 169.516 grams
Mass of empty container #2: 170.396 grams
Mass correction factor: 0.030
Average mass change: -0.404 percent
General comments (publicly viewable) (Max 1000 characters): MASS CHANGE
Test was verified on 11/6/2025 ✔