Summary for Test 2025-10-26-10-1
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 1000510 DEA: 060W79U4 EFIS: 0622000189 |
|---|---|
| DIST-CO-RTE-PM | 06-KER,TUL-99-56.4/57.6,0.0/13.5 |
| Award Date | 04/10/2025 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC. |
| Location Description | KERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING |
| QA Service Level | 1 (Verified on 08/26/2024) |
Sample Information
| Sample Taken Date | 10/26/2025 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/03/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 100% pure |
| The quantity of what the sample constitutes | 1 Jug | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | MIKE | Last name of sampler or witnessed by | BROOKS |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Centennial Asphalt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 754248 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | 100% pure |
Test Details
DIME Sample ID: 2025-10-26-10
DIME Test ID: 2025-10-26-10-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2025-11-06
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Luis Maca
Date of test: 11/05/2025
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 180.5 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 150.2 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 179.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 149.2 g
Beaker 1 Residue: 60.6 %
Beaker 2 Residue: 60.4 %
Percentage of residue: 61 %
General comments (publicly viewable) (Max 1000 characters): EVAP
Test was verified on 11/6/2025 ✔