Summary for Test 2025-10-29-38-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1000416 DEA: 120S1104 EFIS: 1219000091 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-22-R0.9/R9.4 |
| Award Date | 09/04/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE CONCRETE BARRIER AND MODIFY LIGHTING SYSTEM. |
| Location Description | ORANGE FROM BOLSA CHICA ROAD OVERCROSSING IN GARDEN GROVE TO LEWIS STREET OVERCROSSING IN ORANGE |
| QA Service Level | 1 (Verified on 08/05/2024) |
Sample Information
| Sample Taken Date | 10/29/2025 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Mahesh | Last name of sampler or witnessed by | Kapoor |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 25-0370 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | National / Irvine | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | A59C456T10 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 111823 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | Median Barrier Euclid Bridge UC 310+60~310+90 |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-10-29-38
DIME Test ID: 2025-10-29-38-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-11-05
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Dan Morris
Date of test: 11/05/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 30590 lb
Maximum load on cylinder 2: 28760 lb
Maximum load on cylinder 3: 29280 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 2433.6 psi
Compressive strength of cylinder 2: 2288.0 psi
Compressive strength of cylinder 3: 2329.4 psi
Compressive strength (to nearest 10 psi): 2350 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 25-0370 | 138.83 KB | 11/05/2025 | 2025-10-29-38-1 | Info |
Test was verified on 11/5/2025 ✔