Summary for Test 2025-10-06-70-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000435
DEA: 030J01U4
EFIS: 0323000244
DIST-CO-RTE-PM03-PLA-28-0.1/11.0
Award Date10/02/2024
Closeout DateNot set
Work DescriptionHMA (TYPE A), COLD PLANE AC PVMT, RDWY EXC, & CL 2 AB.
Location DescriptionPLACER COUNTY FROM 0.1 MILE EAST OF ROUTE 89 AT TAHOE CITY TO THE NEVADA STATE LINE AT KINGS BEACH
QA Service Level1 (Verified on 07/30/2024)

Sample Information

Sample Taken Date10/06/2025 Sample Unique Key70
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/14/2025
Sample typeQuality Assurance A brief description of the sample3/4" HMA w/ 25% RAP
The quantity of what the sample constitutes2 Boxes From where was the sample collectedSource
First name of sampler or witnessed byEmilio Last name of sampler or witnessed byChavez
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 25-222 Linked DIME Sample ID2025-10-06-45
The fabricator/manufacturer/facility nameTeichert Martis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number6 HMA Mix Number30540732407P
Binder content (%)5.0 Virgin binder PG
Design binder PG PG 64-28 Binder SupplierPNW
RAP content (%)15 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2025-10-06-70
DIME Test ID: 2025-10-06-70-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-04

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 11/03/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2295.3 g
Mass Loss: 127.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.35 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.22 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2025