Summary for Test 2025-10-30-23-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993253 DEA: 033F0604 EFIS: 0312000052 |
|---|---|
| DIST-CO-RTE-PM | 03-GLE-162-76.3/78.6 |
| Award Date | 02/02/2022 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 10/30/2025 | Sample Unique Key | 23 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA w/ 25% RAP |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Atterberry |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Daily 25-242 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C803786 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 4 |
| Sublot number | 1 | HMA Mix Number | 30940432407V |
| Binder content (%) | 4.7 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 15 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2025-10-30-23
DIME Test ID: 2025-10-30-23-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-11-03
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 10/31/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7342.7 grams
Mass of oven-dry sample in air for Sample 1: 2603.2 grams
Mass of container filled with the sample and water for Sample 1: 8943 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.596
Theoretical maximum density at 25°C (77°F): 2588.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/3/2025 ✔