Summary for Test 2025-10-21-31-8

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date10/21/2025 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/22/2025
Sample typeProduction Start-Up A brief description of the sampleRPSU
The quantity of what the sample constitutes12 Bags From where was the sample collectedSupplier
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identification25-10-21-31-RPSU Linked DIME Sample ID2025-10-21-37
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0036
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number23418180AH MM

Test Details

DIME Sample ID: 2025-10-21-31
DIME Test ID: 2025-10-21-31-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2025-10-31

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Number
Dimensional ratio used: 5:1
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 10/30/2025
Percentage on the 6 inch sieve: 0 %
Percentage on the 5 inch sieve: 0 %
Percentage on the 4 ½ inch sieve: 0 %
Percentage on the 4 inch sieve: 0 %
Percentage on the 3 ½ inch sieve: 0 %
Percentage on the 3 inch sieve: 0 %
Percentage on the 2 ½ inch sieve: 0 %
Percentage on the 2 inch sieve: 0 %
Percentage on the 1 ½ inch sieve: 0 %
Percentage on the 1 inch sieve: 0 %
Percentage on the ¾ inch sieve: 0 %
Percentage on the ½ inch sieve: 0 %
Percentage on the ⅜ inch sieve: 0 %
Percentage on the ¼ inch sieve: 0 %
Percentage on the No. 4 sieve: 0 %
Number of 6 inch that were flat and elongated: 0 particles
Number of 6 inch that were not flat and elongated: 0 particles
Number of 5 inch that were flat and elongated: 0 particles
Number of 5 inch that were not flat and elongated: 0 particles
Number of 4 ½ inch that were flat and elongated: 0 particles
Number of 4 ½ inch that were not flat and elongated: 0 particles
Number of 4 inch that were flat and elongated: 0 particles
Number of 4 inch that were not flat and elongated: 0 particles
Number of 3 ½ inch that were flat and elongated: 0 particles
Number of 3 ½ inch that were not flat and elongated: 0 particles
Number of 3 inch that were flat and elongated: 0 particles
Number of 3 inch that were not flat and elongated: 0 particles
Number of 2 ½ inch that were flat and elongated: 0 particles
Number of 2 ½ inch that were not flat and elongated: 0 particles
Number of 2 inch that were flat and elongated: 0 particles
Number of 2 inch that were not flat and elongated: 0 particles
Number of 1 ½ inch that were flat and elongated: 0 particles
Number of 1 ½ inch that were not flat and elongated: 0 particles
Number of 1 inch that were flat and elongated: 0 particles
Number of 1 inch that were not flat and elongated: 0 particles
Number of ¾ inch that were flat and elongated: 0 particles
Number of ¾ inch that were not flat and elongated: 100 particles
Number of ½ inch that were flat and elongated: 0 particles
Number of ½ inch that were not flat and elongated: 100 particles
Number of ⅜ inch that were flat and elongated: 0 particles
Number of ⅜ inch that were not flat and elongated: 100 particles
Number of ¼ inch that were flat and elongated: 0 particles
Number of ¼ inch that were not flat and elongated: 0 particles
Number of No. 4 that were flat and elongated: 0 particles
Number of No. 4 that were not flat and elongated: 100 particles
Percentage (by number) of 6 inch particles that were flat and elongated: 0 %
Percentage (by number) of 6 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 5 inch particles that were flat and elongated: 0 %
Percentage (by number) of 5 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 4 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 4 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 4 inch particles that were flat and elongated: 0 %
Percentage (by number) of 4 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 3 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 3 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 3 inch particles that were flat and elongated: 0 %
Percentage (by number) of 3 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 2 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 2 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 2 inch particles that were flat and elongated: 0 %
Percentage (by number) of 2 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 1 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 1 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 1 inch particles that were flat and elongated: 0 %
Percentage (by number) of 1 inch particles that were not flat and elongated: 0 %
Percentage (by number) of ¾ inch particles that were flat and elongated: 0 %
Percentage (by number) of ¾ inch particles that were not flat and elongated: 100 %
Percentage (by number) of ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of ½ inch particles that were not flat and elongated: 100 %
Percentage (by number) of ⅜ inch particles that were flat and elongated: 0 %
Percentage (by number) of ⅜ inch particles that were not flat and elongated: 100 %
Percentage (by number) of ¼ inch particles that were flat and elongated: 0 %
Percentage (by number) of ¼ inch particles that were not flat and elongated: 0 %
Percentage (by number) of No. 4 particles that were flat and elongated: 0 %
Percentage (by number) of No. 4 particles that were not flat and elongated: 100 %
Weighted percentage of particles (by number) that were flat and elongated: 0 %
Weighted percentage of particles (by number) that were not flat and elongated: 0 %
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 10/31/2025