Summary for Test 2017-12-12-1-3
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212862 DEA: 101G5504 EFIS: 1016000217 MINOR: 10A1892 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-49- |
| Award Date | Not set |
| Closeout Date | 12/28/2022 |
| Work Description | Construct two material storage bins |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/11/2017) |
Sample Information
| Sample Taken Date | 12/12/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/14/2017 | Sample type | Quality Assurance |
| A brief description of the sample | 1-1/8 x 54 F1554 Rod, 2x2 plate washer, 1-1/8 HVY Hex A563 | The quantity of what the sample constitutes | 1 sampled 16 total |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Ryan |
| Last name of sampler or witnessed by | Cummings | Title of sampler | QA |
| Telephone number of sampler | 916-718-7759 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Robert JFrank |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-260-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 145917 | Nut Mfg. Lot Number(s) | 21979-6213174808 |
| Washer Mfg. Lot Number(s) | PL1710376451 | Bolt Specification | F1554 Grade 36 |
| Bolt Length(s) | 54" | Nut Specification | A563 |
| Washer Specification | A36 | Finish | HDG |
| Diameter/Size | 1-1/8 x 54 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-12-12-1
DIME Test ID: 2017-12-12-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-12-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/14/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | S29-260-17 | 1 1/8-7 Hex | 116830 | 519.69 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 12/14/2017 ✔