Summary for Test 2017-12-12-4-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212253 DEA: 010H0304 EFIS: 0117000087 |
---|---|
DIST-CO-RTE-PM | 01-HUM-96-20.0/24.0, 0.83 |
Award Date | 02/22/2017 |
Closeout Date | 01/08/2019 |
Work Description | REPAIR SLIPOUT |
Location Description | IN HUMBOLDT COUNTY NEAR WEITCHPEC FROM 3.0 MILES OF KLAMATH RIVER BRIDGE #04-0144 TO 0.6 MILE EAST OF WEITCHPEC ROAD |
QA Service Level | 1 (Verified on 04/24/2017) |
Sample Information
Sample Taken Date | 12/12/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2017 |
Sample type | Quality Assurance | A brief description of the sample | Bar Lock Standard Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | McCracken |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerdau Nucor | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau Nucor |
Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5, 6 | Coupler Model | Barlock |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 6 149301, 149973, 5 148253 | Rebar Heat Number(s) | 6 6502864802, 6502911202 5 6502875902, |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-12-12-4
DIME Test ID: 2017-12-12-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-12-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/14/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #5/16mm | 0.31 | 0 | 27738 | 89477 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 12/18/2017 ✔