Summary for Test 2025-10-07-68-5

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 1001059
DEA: 112N2334
EFIS: 1124000191
DIST-CO-RTE-PM11-SD-5,15-Var
Award Date05/22/2025
Closeout Date05/29/2026
Work DescriptionMICROSURFACING, COLD PLANE, HMA TYPE A, SIGN INSTALLATION & STRIPING.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/30/2025)

Sample Information

Sample Taken Date10/07/2025 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing10/13/2025 Sample typeVerification
A brief description of the sampleEmulstion The quantity of what the sample constitutes2qt, one container
From where was the sample collectedSource First name of sampler or witnessed bymusfiq
Last name of sampler or witnessed byAli Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSubstanable Emuision
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeMSE
Lot NumberNot set Sub LotNot set
Dilution Percentage RateN/A

Test Details

DIME Sample ID: 2025-10-07-68
DIME Test ID: 2025-10-07-68-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2025-11-04

Test Results


Is Correction factor required?: Yes
Input Type: Calculated
Tester's full name: David Valenzuela
Date of test: 10/21/2025
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 0.1 sec
Efflux time for determination of the correction factor (ETCF1): 0.1 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 1.0 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 31.9 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 34 sec
Test efflux temperature: 25 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2025 ✔