Summary for Test 2025-10-02-49-5
Test performed: ASTM D2487-17Project Information
| Project Identifiers | Project ID: 1001796 DEA: 021K5404 EFIS: 0224000119 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-44-R26.94/R27.62 |
| Award Date | 05/02/2028 |
| Closeout Date | Not set |
| Work Description | West Shingletown Shoulder Widening and Rumble Strips |
| Location Description | In Shasta County at Shingletown from 1.0 Mile West to 0.2 Mile west of Wilson Hil Road |
| QA Service Level | 1 (Verified on 10/28/2025) |
Sample Information
| Sample Taken Date | 10/02/2025 | Sample Unique Key | 49 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2025 |
| Sample type | Preliminary | A brief description of the sample | 2 Bags Sand Silt Rock and Soil |
| The quantity of what the sample constitutes | Structural Section Recommendation | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derek | Last name of sampler or witnessed by | Serna |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | D80072 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | District 2 Lab | Transportation Laboratory (TL) Number | 897620 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder at SHA 44, PM 27.5 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-10-02-49
DIME Test ID: 2025-10-02-49-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: ASTM D2487-17: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
Test Release Date: 2025-10-29
Test Results
Units for Particle Size: millimeters
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 10/28/2025
Percentage of plus 3-in. (75-mm) material: 0 %
Maximum particle size: 25 millimeters
Fines classification: Silty
Percent fines: 36 %
Percent sand: 49 %
Percent gravel: 15 %
Liquid limit: 46
Plasticity Index: 14
Is soil fine-grained or coarse-grained?: coarse-grained
Fine-grained soil classification: no data
Inorganic clay classification: no data
Inorganic silt classification: no data
Organic fine-grained soil classification: no data
Any descriptors added to fine-grained soil classification?: "with gravel"
Coarse-grained soil classification: sand
Particle-size diameter at 10% passing (D10): 0.0187 millimeters
Particle-size diameter at 30% passing (D30): 0.059 millimeters
Particle-size diameter at 60% passing (D60): 0.79 millimeters
Gravel classification: silty
Sand classification: silty sand - SM; silty
Any descriptors added to coarse-grained soil classification?: "with gravel"
Did field sample contain cobbles or boulders?: no data
Coarse-grained soil dual classification: no data
Descriptive information: 0
Coefficient of uniformity (Cu): 42.246
Coefficient of curvature (Cc): 0.236
General comments (publicly viewable) (Max 1000 characters): A silty sand with gravel, (SM)g
Test was verified on 10/29/2025 ✔