Summary for Test 2017-12-13-2-2

Test performed: AASHTO T27-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date12/13/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/13/2017
Sample typeQuality Control A brief description of the sampleNA
The quantity of what the sample constitutesNA From where was the sample collectedOther
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Test
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedNA
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2017-12-13-2
DIME Test ID: 2017-12-13-2-2
Testing Lab: CT HQ - QAM Sacramento Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2017-12-20

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 12/13/2017
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 85 %
Cumulative percent passing the 1/2 in. sieve: 20 %
Cumulative percent passing the 3/8 in. sieve: 5 %
Cumulative percent passing the 1/4 in. sieve: 2 %
Cumulative percent passing the #4 sieve: 2 %
Cumulative percent passing the #8 sieve: 2 %
Cumulative percent passing the #16 sieve: 2 %
Cumulative percent passing the #30 sieve: 2 %
Cumulative percent passing the #50 sieve: 2 %
Cumulative percent passing the #100 sieve: 2 %
Cumulative percent passing the #200 sieve: 1.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/13/2017

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.