Summary for Test 2025-10-10-50-5
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/10/2025 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2025 |
| Sample type | Verification | A brief description of the sample | Tank 868 |
| The quantity of what the sample constitutes | 2 of 2 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Molly | Last name of sampler or witnessed by | Gibney |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | AC-3262-WS | Linked DIME Sample ID | 2025-10-10-23 |
| The fabricator/manufacturer/facility name | West Sacramento,CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | VSS Emultech - West Sacramento CA | Multigrade | No |
| Multigrade Type | PG 64-28 / PG 64-16 / PG 64-10 | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-10-10-50
DIME Test ID: 2025-10-10-50-5
Testing Lab: ABT Group
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-10-28
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: No
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 10/24/2025
Any material loss from containers during heating process/testing?: no data
Mass of container #1 before test (m1i): 212.194 grams
Mass of container #2 before test (m2i): 209.342 grams
Mass of container #1 after test (m1f): 212.065 grams
Mass of container #2 after test (m2f): 209.214 grams
Mass of empty container #1: 176.915 grams
Mass of empty container #2: 174.008 grams
Average mass change: -0.364 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 10/28/2025 ✔