Summary for Test 2025-10-10-50-4

Test performed: AASHTO T51-22

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/10/2025 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2025
Sample typeVerification A brief description of the sampleTank 868
The quantity of what the sample constitutes2 of 2 From where was the sample collectedManufacturer
First name of sampler or witnessed byMolly Last name of sampler or witnessed byGibney
Title of sampler Telephone number of sampler
Laboratory sample identificationAC-3262-WS Linked DIME Sample ID2025-10-10-23
The fabricator/manufacturer/facility nameWest Sacramento,CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierVSS Emultech - West Sacramento CA MultigradeNo
Multigrade TypePG 64-28 / PG 64-16 / PG 64-10 Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-10-10-50
DIME Test ID: 2025-10-10-50-4
Testing Lab: ABT Group
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2025-10-28

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 10/24/2025
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of test #3 (D3): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Ductility

Test was verified on 10/28/2025