Summary for Test 2025-10-15-36-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001065
DEA: 070Y1304
EFIS: 0724000134
DIST-CO-RTE-PM07-VEN-101-25.9/30.6
Award Date05/22/2025
Closeout Date05/29/2026
Work DescriptionMAINLINE INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY IN VENTURA FROM 0.1 MILE WEST OF TELEPHONE RD UNDERCROSSING TO VENTURA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 07/01/2025)

Sample Information

Sample Taken Date10/15/2025 Sample Unique Key36
Date that the sample was received by the laboratory/organization performing the testing10/22/2025 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byCesar
Last name of sampler or witnessed byCesar QC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namevulcan saticoy
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-10-15-36
DIME Test ID: 2025-10-15-36-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-10-28

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 10/24/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 207.829 grams
Mass of container #2 before test (m2i): 208.009 grams
Mass of container #1 after test (m1f): 207.791 grams
Mass of container #2 after test (m2f): 207.972 grams
Mass of empty container #1: 172.801 grams
Mass of empty container #2: 172.878 grams
Mass correction factor: 0.006
Average mass change: -0.101 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/28/2025 ✔