Summary for Test 2014-02-14-13454655-1

Test performed: ASTM C143-10a

Project Information

Project IdentifiersProject ID: 10016
DEA: 06342524
EFIS: 0600000381
DIST-CO-RTE-PM06-FRE-180-R71.8/74.5
Award Date04/23/2013
Closeout Date10/19/2020
Work DescriptionNEW EXPRESS HIGHWAY
Location DescriptionFRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE
QA Service Level1 (Verified on 07/23/2013)

Sample Information

Sample Taken Date02/14/2014 Sample Unique Key13454655
Date that the sample was received by the laboratory/organization performing the testing02/15/2014 Sample typeQuality Control
A brief description of the sampleType II Cement The quantity of what the sample constitutes8 cylinders
From where was the sample collectedOther First name of sampler or witnessed byJoshua
Last name of sampler or witnessed byGuilmette Title of samplerQC Field Technician/Inspector
Telephone number of sampler(559) 292-2188 Laboratory sample identification2014-02-14-006
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameHwy 180 Mainling Bridge Deck
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierHwy 180 at Fowler Switch Canal Structure nameHwy 180 at Fowler Switch Canal
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND14505
The truck number from where the sample was collected9474 The batch plant ticket number from where the sample was collected114104647
Concrete batch plant114 The fabricator/manufacturer designation for the samplePlant
A detailed description of where the material sample was collectedHwy 180 at Fowler Switch Canal Where the material sample would have been placed if not sampledHwt 180 at Fowler Switch Canal
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-02-14-13454655
DIME Test ID: 2014-02-14-13454655-1
Testing Lab: Trinity Engineering Laboratories, Incorporated - Fresno
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Test Release Date: 2014-04-02

Test Results


Input Type: Calculated
Tester's full name: Joshua Guilmette
Date of test: 02/14/2014
Slump: 5.5 inch
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/2/2014 ✔