Summary for Test 2025-10-15-36-5
Test performed: AASHTO T316-22Project Information
| Project Identifiers | Project ID: 1001065 DEA: 070Y1304 EFIS: 0724000134 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-25.9/30.6 |
| Award Date | 05/22/2025 |
| Closeout Date | 05/29/2026 |
| Work Description | MAINLINE INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | VENTURA COUNTY IN VENTURA FROM 0.1 MILE WEST OF TELEPHONE RD UNDERCROSSING TO VENTURA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/01/2025) |
Sample Information
| Sample Taken Date | 10/15/2025 | Sample Unique Key | 36 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/22/2025 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder Sample | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Cesar |
| Last name of sampler or witnessed by | Cesar QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | vulcan saticoy | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-10-15-36
DIME Test ID: 2025-10-15-36-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-10-28
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: David Valenzuela
Date of test: 10/24/2025
Time of test: 8:05 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 48.4 %
Viscosity reading #1 (A) : 0.239 Pa-s
Viscosity reading #2 (B) : 0.241 Pa-s
Viscosity reading #3 (C): 0.246 Pa-s
Average viscosity: 0.242 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/28/2025 ✔