Summary for Test 2025-10-15-23-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.5/6.8 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC). |
| Location Description | TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 10/15/2025 | Sample Unique Key | 23 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 |
| The quantity of what the sample constitutes | 9 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Breanna | Last name of sampler or witnessed by | Flores |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | 1079-1015 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | 1079-1015 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | n/p |
|---|---|---|---|
| The truck number from where the sample was collected | 10067316 | The batch plant ticket number from where the sample was collected | 31777706 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | SB15 EMPIRE CREEK BENT 2 , COLUMN WRAP | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-10-15-23
DIME Test ID: 2025-10-15-23-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-10-24
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/22/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 51260 lb
Maximum load on cylinder 2: 51340 lb
Maximum load on cylinder 3: 53170 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4058.6 psi
Compressive strength of cylinder 2: 4064.9 psi
Compressive strength of cylinder 3: 4209.8 psi
Compressive strength (to nearest 10 psi): 4110 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/24/2025 ✔