Summary for Test 2025-10-20-8-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1000850
DEA: 061G8204
EFIS: 0624000169
DIST-CO-RTE-PM06-FRE-33-46.8/47.4,53.4/61.4
Award Date04/01/2025
Closeout DateNot set
Work DescriptionPARTIAL DEPTH RECYCLING AND HMA.
Location DescriptionFRESNO COUNTY IN AND NEAR MENDOTA FROM 0.4 MILE NORTH OF KAMM AVENUE TO MOUNTAIN VIEW AVENUE AND FROM ADAMS AVENUE TO BELMONT AVENUE
QA Service Level1 (Verified on 12/16/2024)

Sample Information

Sample Taken Date10/20/2025 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2025
Sample typeAcceptance A brief description of the sample1/2 HMA Type A
The quantity of what the sample constitutes1500-2250 Tons @ 1523T From where was the sample collectedManufacturer
First name of sampler or witnessed bytomas Last name of sampler or witnessed bySilva
Title of samplerMREA Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJaxon Baker/ LeGrand Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number2
Sublot number20 HMA Mix Number25131
Binder content (%)4.8 Virgin binder PG PG 70-10
Design binder PG Binder SupplierSJR
RAP content (%)15 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2025-10-20-8
DIME Test ID: 2025-10-20-8-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-10-23

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 10/21/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3991.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 5611.0 g
Mass of HMA Sample prior to ignition: 1619.5 g
Mass Loss: 90.6 g
Mass of aggregate remaining after ignition: 1528.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.70 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.89 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/23/2025