Summary for Test 2025-10-16-6-2
Test performed: ASTM A775-19Project Information
| Project Identifiers | Project ID: 1000576 DEA: 120R3134 EFIS: 1220000025 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-91-6.4/R9.2 |
| Award Date | 11/26/2024 |
| Closeout Date | Not set |
| Work Description | PLACE JPCP, REMOVE CONC PVMT AND BASE, AND MODIFY ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN ANAHEIM FROM 0.3 MILE EAST OF ROUTE 91/57 SEPARATION TO 0.1 MILE EAST OF ROUTE 91/55 SEPARATION |
| QA Service Level | 1 (Verified on 10/17/2024) |
Sample Information
| Sample Taken Date | 10/16/2025 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #6 rebar x 30" |
| The quantity of what the sample constitutes | 4037 each | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joaquin | Last name of sampler or witnessed by | Moreno |
| Title of sampler | Joaquin | Telephone number of sampler | 9095268064 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Pacific Highway Products | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L161-023-25 | Structure unique identifier | |
| Structure name | Bid Item | 3908732 |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4400037430 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | CH0665YM | Rebar Coating Specification | ASTM A775 |
| Rebar Size (#) | #6 | Rebar Coating Color | Green |
| Rebar Manufacturer | Nucor steel | Rebar Coater | Simcote Inc |
| Rebar Powder Manufacturer | Sherwin Williams | Release Number | |
| Quality Assurance Code |
Test Details
DIME Sample ID: 2025-10-16-6
DIME Test ID: 2025-10-16-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2025-10-23
Test Results
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 10/23/2025
Total Number of Holiday: 0
Total Length: 5
Holidays Per Linear Foot of Bar: 0
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/23/2025 ✔