Summary for Test 2025-10-15-25-3

Test performed: ASTM D36-14ε1

Project Information

Project IdentifiersProject ID: 1000996
DEA: 101S6404
EFIS: 1024000105
DIST-CO-RTE-PM10-MER-165-L0.0/7.0,8.7/16.5
Award Date05/13/2025
Closeout DateNot set
Work DescriptionRESURFACE PAVEMENT WITH RHMA AND HMA.
Location DescriptionMERCED COUNTY IN AND NEAR LOS BANOS FROM 0.3 MILE SOUTH OF POLE LINE ROAD TO 0.2 MILE SOUTH OF MASON ROAD AND FROM 0.1 MILE SOUTH OF CANAL FARM LANE TO 1.4 MILES NORTH OF WOLFSEN ROAD
QA Service Level1 (Verified on 04/18/2025)

Sample Information

Sample Taken Date10/15/2025 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2025
Sample typeQuality Assurance A brief description of the sample64-16 RUBBER
The quantity of what the sample constitutes1 CAN OF RUBBER From where was the sample collectedSource
First name of sampler or witnessed byJ Last name of sampler or witnessed byTOSTADO
Title of samplerTECHNICIAN Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina Chowchilla Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form000117 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-10-15-25
DIME Test ID: 2025-10-15-25-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2025-10-22

Test Results


ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 10/22/2025
Softening Point Sample 1: 70 C
Softening Point Sample 2: 69 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): SOFTENING POINT

Test was verified on 10/22/2025