Summary for Test 2025-10-10-31-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1000957 DEA: 022K5404 EFIS: 0225000091 |
|---|---|
| DIST-CO-RTE-PM | 02--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 03/21/2025) |
Sample Information
| Sample Taken Date | 10/10/2025 | Sample Unique Key | 31 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 2 Bags RAP |
| The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D80082B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) — Latona Aggregates (Anderson, CA) | Transportation Laboratory (TL) Number | 876965 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2025-10-10-31
DIME Test ID: 2025-10-10-31-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-10-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 10/15/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7331 grams
Mass of oven-dry sample in air for Sample 1: 1647.3 grams
Mass of container filled with the sample and water for Sample 1: 8337.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.571
Theoretical maximum density at 25°C (77°F): 2563.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmm=2.571
Test was verified on 10/22/2025 ✔