Summary for Test 2025-10-08-58-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1001219 DEA: 021J8904 EFIS: 0221000006 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-R30.5/R31.0 |
| Award Date | 07/02/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE PAVEMENT AND PLACE POLYESTER CONCRETE OVERLAY. |
| Location Description | SHASTA COUNTY NEAR O\'BRIEN FROM 0.1 MILE SOUTH OF TUNNEL GULCH VIADUCT TO THE O\'BRIEN REST AREA |
| QA Service Level | 1 (Verified on 05/05/2025) |
Sample Information
| Sample Taken Date | 10/08/2025 | Sample Unique Key | 58 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/09/2025 | Sample type | Production Start-Up |
| A brief description of the sample | 1 Bag of RAP | The quantity of what the sample constitutes | Production Start Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Giuliano |
| Last name of sampler or witnessed by | Giuntoli | Title of sampler | JET |
| Telephone number of sampler | Laboratory sample identification | D80077B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | JF Shea Construction — Fawndale Rock and Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 877603 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | 3932161 |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale Rock and Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2025-10-08-58
DIME Test ID: 2025-10-08-58-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-10-20
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 10/14/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7331 grams
Mass of oven-dry sample in air for Sample 1: 1599.5 grams
Mass of container filled with the sample and water for Sample 1: 8308 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.569
Theoretical maximum density at 25°C (77°F): 2561.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.569
Test was verified on 10/20/2025 ✔