Summary for Test 2025-08-23-22-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date08/23/2025 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing08/23/2025 Sample typeQuality Assurance
A brief description of the sampleJPCP beams The quantity of what the sample constitutes10 CY
From where was the sample collectedJob Site First name of sampler or witnessed byFernando
Last name of sampler or witnessed byCarranza Title of samplerMaterials Tester
Telephone number of sampler Laboratory sample identification25-2851
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM24015
The truck number from where the sample was collectedTruck 5 The batch plant ticket number from where the sample was collectedLoad 1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampledJobsite
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-08-23-22
DIME Test ID: 2025-08-23-22-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2025-10-17

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Fernando Carranza
Date of test: 09/20/2025
Identification number: 25-2851
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.1 inch
Depth of specimen 3: 6.0 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9323 lb
Maximum load applied 2: 9099 lb
Maximum load applied 3: 9121 lb
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Modulus of rupture: 775 psi
Modulus of rupture 2: 745 psi
Modulus of rupture 3: 760 psi
Modulus of rupture average: 760 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/17/2025 ✔