Summary for Test 2025-10-06-56-4

Test performed: AASHTO T269-24E25

Project Information

Project IdentifiersProject ID: 994901
DEA: 112T3434
EFIS: 1120000081
DIST-CO-RTE-PM11-SD-805-5.1/8.3
Award Date01/29/2024
Closeout DateNot set
Work DescriptionSOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
QA Service Level1 (Verified on 03/21/2024)

Sample Information

Sample Taken Date10/06/2025 Sample Unique Key56
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2025
Sample typeProduction Start-Up A brief description of the samplePSU
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byMasud
Title of sampler Telephone number of sampler
Laboratory sample identification25-10-06-56-PSU Linked DIME Sample ID2025-10-06-57
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200 Otay Val
Binder content (%)4.7 Virgin binder PG PG58-16
Design binder PG PG 64-16 Binder SupplierValero
RAP content (%)22 WMA AdditivesNo
Antistrip typeNone

Test Details

DIME Sample ID: 2025-10-06-56
DIME Test ID: 2025-10-06-56-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2025-10-17

Test Results


Is the sample lab compacted or field compacted?: Lab compacted
Number of tests: 3
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 10/16/2025
Bulk Specific Gravity: 2.389
Bulk Specific Gravity 2: 2.388
Bulk Specific Gravity 3: 2.374
Theoretical Maximum Specific Gravity: 2.505
Percent Air Voids: 4.6 %
Percent Air Voids 2: 4.7 %
Percent Air Voids 3: 5.2 %
Average Percent Air Voids: 4.8 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 4.0% Tested an Avg of 4.8 %

Test was verified on 10/17/2025