Summary for Test 2025-10-11-4-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1001065
DEA: 070Y1304
EFIS: 0724000134
DIST-CO-RTE-PM07-VEN-101-25.9/30.6
Award Date05/22/2025
Closeout DateNot set
Work DescriptionMAINLINE INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY IN VENTURA FROM 0.1 MILE WEST OF TELEPHONE RD UNDERCROSSING TO VENTURA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 07/01/2025)

Sample Information

Sample Taken Date10/11/2025 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2025
Sample typeAcceptance A brief description of the sampleISR-RSC Beams
The quantity of what the sample constitutes200 CY From where was the sample collectedJob Site
First name of sampler or witnessed byKris Last name of sampler or witnessed byLopez
Title of samplerRMA QC Telephone number of sampler
Laboratory sample identification25-3284 Linked DIME Sample ID
The fabricator/manufacturer/facility nameShort Load Concrete Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-10-11-4
DIME Test ID: 2025-10-11-4-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-10-15

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 10/14/2025
Identification number: Set #1
Width of specimen: 5.9375 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6.125 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7055 lb
Maximum load applied 2: 7760 lb
Maximum load applied 3: 7425 lb
Curing history and apparent moisture condition of the specimen: Yes
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: None
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 620 psi
Modulus of rupture 2: 670 psi
Modulus of rupture 3: 640 psi
Modulus of rupture average: 640 psi
General comments (publicly viewable) (Max 1000 characters): NB US-101 Main St. & Seaward Ave.

Test was verified on 10/15/2025