Summary for Test 2017-11-29-18-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 209141
DEA: 07215954
EFIS: 0700001835
DIST-CO-RTE-PM07-LA-5-0.0/7.6
Award Date04/24/2014
Closeout Date07/14/2022
Work DescriptionWIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location DescriptionLOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
QA Service Level1 (Verified on 06/02/2014)

Sample Information

Sample Taken Date11/29/2017 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing12/04/2017 Sample typeQuality Assurance
A brief description of the sampleCoupon Casting The quantity of what the sample constitutes2
From where was the sample collectedDistributor First name of sampler or witnessed byDebbie
Last name of sampler or witnessed byOzuna Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameDSI Manchester Metals
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)16K17, 17K17
Part Number (s)680270212 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Manchester Metals
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2017-11-29-18
DIME Test ID: 2017-11-29-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-12-14

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 12/07/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
116K170.5030.1987517628699011.5Fred
217K170.5030.1987500308126016.1Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 12/7/2017 ✔