Summary for Test 2017-11-30-4-11
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 211226 DEA: 024E6404 EFIS: 0212000011 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-147-8.9/9.3 |
| Award Date | 05/10/2016 |
| Closeout Date | 11/12/2020 |
| Work Description | REPLACE BRIDGE, GUARDRAILING, HMA, STRIPING |
| Location Description | PLUMAS COUNTY ABOUT 9 MILES NORTH OF CANYON DAM FROM 0.1 MILE SOUTH TO 0.4 MILE NORTH OF HAMILTON BRANCH BRIDGE |
| QA Service Level | 1 (Verified on 04/21/2016) |
Sample Information
| Sample Taken Date | 11/30/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
| The quantity of what the sample constitutes | 72 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | QAI | Telephone number of sampler | 510 693-3545 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-081-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | NF14203689 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
| Bolt Length(s) | 4" | Nut Specification | DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 349424, G8338 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-11-30-4
DIME Test ID: 2017-11-30-4-11
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-12-14
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 12/07/2017
Sample No.: 1D
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: G8338, 349424A
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 N
Size: .5 in
Bolt Length: 4 in
Measurement Average: 3.71 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/7/2017 ✔